Number: A1TH083090U492
Subject: Error "Device fault reading drive"
Date: December 11, 1990
- - - - - - - - - - - - - - - - - - - - - - - - -
PROBLEM: A customer was receiving this error message on his
workstation: "Device fault reading drive h:" (or any
network drive). The customer was using NetWare 386 v3.1 and
Token-Ring 16/4 adapters on the workstation with the LAN
support shell.
SOLUTION: Change the buffer size of the Token-Ring in the file server.
This is done by setting the maximum physical packet size
equal to 4202 in the STARTUP.NCF file.
(X) This information was verified verbally