  1. Number:        A1TH083090U492 
  2. Subject:       Error "Device fault reading drive" 
  3. Date:          December 11, 1990
  4. - - - - - - - - - - - - - - - - - - - - - - - - - 
  5.  
  6. PROBLEM:       A customer was receiving this error message on his
  7.                workstation:  "Device fault reading drive h:" (or any
  8.                network drive).  The customer was using NetWare 386 v3.1 and
  9.                Token-Ring 16/4 adapters on the workstation with the LAN
  10.                support shell. 
  11.  
  12. SOLUTION:      Change the buffer size of the Token-Ring in the file server. 
  13.                This is done by setting the maximum physical packet size
  14.                equal to 4202 in the STARTUP.NCF file.
  15.  
  16.                (X)    This information was verified verbally